Semita Nexis · Data center infrastructure

The data center,
shipped in a cabinet.

Factory-integrated micro data centers, single-unit immersion cooling and the cabling that connects them. Delivered pre-assembled and tested, running in days instead of months.

NexisRack RDC-07 row of eight micro data center cabinets with cobalt-lit doors
NexisRack RDC-07 row of eight micro data center cabinets with cobalt-lit doors
1–10
Cabinets per NexisRack system
≤1.4
PUE, NexisRack
4–40 kW
Per NexisImmersion unit
400 G
Nexis Connect optics
Product lines

Three lines. One accountable partner.

From a single branch cabinet to a GPU node and the fiber between them, every layer is designed, supplied and supported by Semita.

NexisRack RDC-01 NexisRack RDC-03
Micro data center

NexisRack

The cabinet is the computer room: UPS, batteries, precision cooling, monitoring and fire suppression in one to ten cabinets.

RDC-01 → RDC-07 3–30 kVA IP5X
NexisImmersion tank unit
Immersion cooling

NexisImmersion

A single-unit immersion tank for GPU and dense compute: servers in dielectric oil, everything in one cabinet.

LCT-04 → LCT-40 Up to 40 kW
Connectivity

Nexis Connect

MPO/MTP® fiber, optics up to 400G, structured copper and out-of-band management.

Fiber Optics Copper · OOB
Solutions

Packaged for the way you compute.

Flagship package

Nexis Edge AI Pod

NexisRack cabinets for networking, storage and general compute, a NexisImmersion unit for GPU-dense inference, and Nexis Connect cabling between them. One delivery, one monitoring view, one support contract.

RDC-02 / RDC-03 + LCT-20 / LCT-40 + Nexis Connect

Discuss an Edge AI Pod
NexisRack RDC-03 NexisImmersion unit
Enterprise

Branch micro DC

Replace a server closet with a sealed, monitored RDC-01 that needs only 0.72 m² and runs quietly beside people.

RDC-01 · 3 kVA · 28U

Networks

Business outlets

Standard cabinets for telecom, finance, energy, broadcasting and retail. Deploy many sites without a survey at each.

RDC-01 / RDC-02 · central monitoring

Edge

Edge hub

Multi-cabinet systems with in-row cooling and large-capacity UPS for regional hubs and campus edge rooms.

RDC-03 / RDC-05 / RDC-07

AI

GPU inference node

A single 21U NexisImmersion unit for small AI clusters where air cooling reaches its limit.

LCT-20 / LCT-40

Telecom

Base station & lab

Compact 13U units on single-phase power for BBUs, liquid cooling trials and near-field compute.

LCT-04 / LCT-06 / LCT-10

Fabric

400G-ready cabling

Pre-terminated fiber and copper designed with the cabinets, certified and documented on handover.

Nexis Connect · MPO · QSFP-DD

From order to operation

Built in the factory. Running on day one.

Cabinets on the production line
Cabinets on the production line

Certified manufacturing

Built under ISO 9001 quality and ISO 14001 environmental management, with CE-certified products and product-level inspection before every shipment.

01

Site survey

Power, space, access path, environment and the workloads you plan to run.

02

Design

RDC or LCT model selection, battery runtime, cabling plan and layout.

03

Factory build

Assembled, wired and tested as a complete machine with standard interfaces.

04

Install

Ships as one unit and is plug-and-play: connect power and network, then commission.

05

Support

Remote monitoring, preventive maintenance and one-stop after-sales service.

Applications

Where Semita Nexis runs.

Telecom Exchange rooms and network edge sites
Banking & finance Branch IT and secure on-premise compute
Energy Substations and control centers
Broadcast Radio and television infrastructure
Retail Store systems and regional hubs
Government & education Secure, monitored edge rooms and campuses
Healthcare Imaging, records and diagnostics
AI & GPU Inference clusters and near-field nodes
Plan your site

Tell us the load. We'll size the system.