Immersion cooling, in a single unit.

NexisImmersion is a complete immersion system in one cabinet. Servers sit in dielectric oil inside a stainless tank, and circulation, heat exchange and controls are built into the same enclosure. Up to 40 kW per unit, with no separate CDU or plant room to design.

  • Six models from 4 to 40 kW, in 13U and 21U tank sizes
  • One unit to place, fill, power and connect
  • Fanless servers and an ultra-quiet room, with PUE close to 1.0
  • Stainless steel wetted parts; mineral, silicone or synthetic oil
  • Mounts standard servers and telecom BBUs, with custom U layouts
NexisImmersion single-unit tank with lid open
NexisImmersion single-unit tank with lid open
Why one unit

Everything immersion needs, inside one cabinet.

Self-contained

Tank, circulation, heat exchange and controls share one enclosure, so there is no CDU, manifold or plant room to engineer.

Single cabinet · single delivery

High density

Direct contact between hardware and oil removes heat far more effectively than air, so GPUs run at full power in less space.

4–40 kW per unit

Efficient

No server fans and low cooling overhead bring PUE close to 1.0 and lower the total cost of ownership.

PUE close to 1.0

Ultra-quiet

With fans removed, the unit runs nearly silently, suitable for offices, labs and shared spaces.

Fanless servers

Protected hardware

Sealed oil keeps out dust and humidity, and every wetted surface is stainless steel for long coolant life.

Stainless · sealed tank

Easy service

Top access door, side or bottom pipe entry, and servicing with the fluid online or offline, close to air-cooled maintenance.

Top access · custom U layout
ONE NEXISIMMERSION UNIT IMMERSION TANK · 13U / 21U HEAT EXCHANGE CIRCULATION 40 °C oil enters at the base 50 °C oil returns from the top
How it works

Chip to coolant, inside one box.

  1. 1
    Hardware is submerged

    Fanless servers or BBUs mount vertically in the tank, fully covered by dielectric oil.

  2. 2
    Oil absorbs heat at the source

    Coolant enters at about 40 °C, flows over every component, and leaves at about 50 °C.

  3. 3
    Built-in heat exchange

    The unit's own exchanger removes the heat from the oil inside the same cabinet.

  4. 4
    Cooled oil returns

    Integrated circulation sends cooled oil back to the base of the tank, and the loop repeats.

Model lineup

Six units, 4 to 40 kW.

Choose by heat load. 13U units run on single-phase power; 21U units on three-phase.

LCT specifications

Heat exchange in kW. Scroll sideways on small screens.

Parameter LCT-04 LCT-06 LCT-1013U LCT-1021U LCT-20 LCT-40
Heat exchange4 kW6 kW10 kW10 kW20 kW40 kW
Available U slots13U21U
Pipe interfaceDN25DN25DN32DN32DN40DN50
Cooling mediumMineral oil, silicone oil, synthetic oil
Oil inlet / outlet40 °C / 50 °C
W × D × H (mm)1200 × 800 × 12501500 × 800 × 1250
Unit weight245 kg350 kg
Power supply1~220 V, 50 Hz3~380 V, 50 Hz
Where it fits

Built for dense compute at the edge.

AI inference GPU nodes for small and medium clusters
Telecom base stations BBUs and edge compute at cell sites
Edge micro DC Dense compute where floor space is scarce
Labs & R&D Liquid cooling validation and test platforms
Plan your site

Tell us the load. We'll size the system.