Copper Connectivity
ANSI/TIA-568.2-D compliant CAT6 U/UTP, CAT6 SF/UTP, armored copper, and structured cabling accessories.
Technical Architecture & Subproduct Scope
Semita Technologies delivers robust twisted-pair copper infrastructure designed for enterprise LANs, industrial networks, and PoE+ / PoE++ applications. We strictly manufacture CAT6 U/UTP and CAT6 SF/UTP configurations (CAT6 F/UTP is excluded), maintaining disciplined separation between unshielded and braid/foil double-shielded offerings.
Need Custom Specifications?
Our application engineering team designs custom connector configurations, core counts, and specialized armoring for telco operators.
Consult Application TeamSelect a Product to View Full Specifications & Gallery
CAT6 U/UTP 4-Pair Solid Horizontal Cable
Semita Category 6 U/UTP unshielded twisted-pair solid horizontal cable is engineered for commercial enterprise structured cabling systems. Built with 23 AWG solid bare electrolytic copper conductors and a central polyethylene cross-separator, it delivers guaranteed 250 MHz transmission performance with exceptional NEXT headroom margin.
Key Engineering Features
- 100% Solid Electrolytic Bare Copper conductors (23 AWG / 0.57 mm)
- Central PE cross-separator preserves geometric pair separation and minimizes NEXT
- Certified 250 MHz bandwidth with significant positive headroom margin
- Supports IEEE 802.3bt Type 4 PoE++ high-power delivery up to 90 Watts
- Compliant with ANSI/TIA-568.2-D and ISO/IEC 11801 Class E international standards
Approved Applications & Deployments
Technical Performance Specifications
| Conductor Material | 100% Solid Bare Electrolytic Annealed Copper |
|---|---|
| Conductor Gauge | 23 AWG (0.57 mm Nominal) |
| Number of Pairs | 4 Twisted Pairs with Central PE Spline |
| Bandwidth Frequency | Tested to 250 MHz (Margin to 500 MHz) |
| PoE Capability | IEEE 802.3bt Type 4 PoE++ (Up to 90W) |
| Jacket Options | CM, CMR Riser, or LSZH (Low Smoke Zero Halogen) |
| Nominal Velocity (NVP) | 68% |
| Max DC Resistance | ≤ 9.38 Ohms / 100m @ 20°C |
| Standards Compliance | ANSI/TIA-568.2-D, ISO/IEC 11801 Class E, RoHS |
CAT6 SF/UTP Double-Shielded Industrial Cable
Semita Category 6 SF/UTP double-shielded cable features an overall aluminum foil screen PLUS a high-coverage tinned copper braid shield. Engineered for factory floors, power substations, and high-EMI industrial environments, it eliminates external electromagnetic interference and prevents high-frequency ground loop noise.
Key Engineering Features
- Double shielding: Overall Aluminum/Mylar Foil + 65% Tinned Copper Braid
- Exceptional screen attenuation (> 75 dB) preventing heavy industrial EMI/RFI
- Disciplined shielding policy: Eliminates ground loops without fragile pair foils
- Heavy-duty industrial-grade outer jacket resistant to oils, abrasions, and chemicals
- Integrates solid drain wire for rapid, reliable 360° shield grounding termination
Approved Applications & Deployments
Technical Performance Specifications
| Shielding Configuration | SF/UTP (Overall Foil Screen + Tinned Copper Braid) |
|---|---|
| Conductor Type | Solid 23 AWG Bare Electrolytic Copper |
| Screen Attenuation | ≥ 75 dB (30 MHz to 1000 MHz) |
| Drain Wire | Tinned Copper Solid Conductor |
| Jacket Material | Flame-Retardant Industrial PVC / LSZH / PUR |
| Bandwidth | 250 MHz Certified |
| PoE Support | IEEE 802.3bt PoE++ (Up to 90W) |
| Operating Temperature | -40°C to +75°C |
Armored CAT6 Direct-Burial Cable
Semita Armored Category 6 direct-burial copper cables are designed for external building interconnections, perimeter security posts, and outdoor industrial yards. Protected by corrugated steel tape (CST) armor and water-blocking gel, they can be directly buried in soil trenches without requiring protective PVC conduit pipes.
Key Engineering Features
- Corrugated Steel Tape (CST) armor delivers impenetrable rodent and crush defense
- Water-blocking petroleum jelly or swellable tape prevents moisture penetration
- Dual UV-resistant High-Density Polyethylene (HDPE) protective sheaths
- Solid 23 AWG pure copper conductors ensure long-distance gigabit PoE performance
- Withstands extreme compressive loads and rough civil backfill compaction
Approved Applications & Deployments
Technical Performance Specifications
| Armor Type | Corrugated Steel Tape (CST) |
|---|---|
| Conductor | 23 AWG Solid Bare Copper (4 Pairs) |
| Waterproofing | Water-Blocking Gel Compound / Swellable Tape |
| Sheathing | Dual Jacket Black UV-Resistant Polyethylene |
| Crush Resistance | 2,500 N / 100 mm |
| Tensile Strength | 1,200 N Installation Tension |
| Water Penetration | IEC 60794-1-2-F5 Compliant |
| Operating Temperature | -40°C to +70°C |
Outdoor UV-Resistant CAT6 PE Cable
Semita Outdoor Category 6 unarmored cable is engineered with a rugged, weather-tight black polyethylene jacket designed to withstand prolonged solar ultraviolet exposure, extreme temperature swings, and rainfall. Ideal for rooftop solar monitoring, mast antennas, and external wall runs.
Key Engineering Features
- Weatherproof black Polyethylene (PE) jacket resists solar degradation and embrittlement
- Water-repellent core prevents moisture damage in humid or outdoor duct routes
- Flexible lightweight design allows easy pulling through external conduit bends
- Solid 23 AWG conductors deliver stable DC power for outdoor PoE cameras
- Certified 250 MHz Category 6 channel performance
Approved Applications & Deployments
Technical Performance Specifications
| Conductor | 23 AWG Solid Bare Copper |
|---|---|
| Jacket Material | Heavy Black UV-Resistant High-Density PE |
| UV Resistance Standard | ASTM G154 / UL 1581 Weather Resistant |
| Bandwidth | 250 MHz |
| PoE Standard | IEEE 802.3at / 802.3bt PoE++ |
| Cold Bend Rating | -40°C |
| Operating Temperature | -40°C to +70°C |
CAT6 & CAT6A Factory Patch Leads
Semita factory-crimped and molded RJ45 patch leads ensure zero-loss interconnects between patch panels, switches, and server ports. Featuring 50-micron gold-plated contact blades, 24 AWG stranded pure copper conductors, and slimline snagless boots, our patch cords eliminate contact corrosion and accidental tab breakage.
Key Engineering Features
- 50-Micron gold plating on contact pins prevents atmospheric oxidation and corrosion
- Molded slimline snagless strain-relief boot protects the retention tab during re-patching
- 24 AWG stranded flexible bare copper conductor withstands frequent bending
- 100% factory component tested for near-end crosstalk (NEXT) and return loss
- Available in U/UTP and SF/UTP double-shielded configurations across multiple lengths
Approved Applications & Deployments
Technical Performance Specifications
| Conductor Type | 24 AWG Multi-Stranded Pure Bare Copper |
|---|---|
| Contact Plating | 50 µ" True Gold over Nickel Plating |
| Connector Type | RJ45 8P8C Snagless Shielded / Unshielded |
| Jacket Material | Low Smoke Zero Halogen (LSZH) / PVC |
| Standard Lengths | 0.5m, 1m, 2m, 3m, 5m, 10m, 15m, 20m |
| Color Options | Blue, Grey, Yellow, Red, Green, Black, White |
| Standards Compliance | ANSI/TIA-568.2-D, ISO/IEC 11801, RoHS |
24-Port Modular Keystone Patch Panels
Semita 19-inch 1U 24-port modular patch panels provide an organized, high-density termination platform for enterprise copper cabling. Designed with a heavy cold-rolled steel frame, rear cable management support bar, and toolless 180-degree Category 6 keystone jacks, they ensure rapid installation and neat cable strain relief.
Key Engineering Features
- 1U 19-Inch 24-Port modular configuration compatible with all standard equipment racks
- Toolless Category 6 keystone jacks feature universal T568A and T568B color coding
- Rear metal cable management bar with cable tie eyelets relieves termination stress
- Sturdy cold-rolled steel panel with electro-deposition black powder coat finish
- Available in shielded (fully metal jacketed) and unshielded variants with grounding lug
Approved Applications & Deployments
Technical Performance Specifications
| Rack Unit Form Factor | 1U (1.75" / 44.45 mm) 19-Inch Standard |
|---|---|
| Port Capacity | 24 Modular Ports (Optional 48-Port 2U) |
| Frame Material | 1.5 mm SPCC Cold-Rolled Steel |
| Keystone Termination | Toolless 180° Snap-In with Dust Covers |
| Wiring Compatibility | T568A & T568B Universal Color-Coded Label |
| Rear Management | Detachable Heavy-Duty Metal Support Bar Included |
| Grounding Terminal | Integrated Ground Wire & M5 Earth Stud (Shielded Model) |
| Standards Compliance | ANSI/TIA-568.2-D, EIA-310-D, UL 1863 |
Deploy High-Reliability Copper Connectivity with Semita
Whether you require customized cable constructions, high-precision optical attenuation tolerances, or fast-track batch delivery across India and global hubs, our engineers are ready to assist.