Brochures & Technical Guides Semita Technologies & Semita Nexis Corporate Overview & Product Specifications 2026 Datasheets
Semita Technologies — Semita & Nexis Contact us
Quality & certifications

Tested before it leaves the factory

Every optical, RF and copper assembly we ship has been measured. Test reports and compliance certificates travel with the order.

Testing

Quality labs

Interferometry & polish

100% of optical patch cords and MPO connectors undergo 3D interferometer geometry inspection and automated end-face defect scanning.

RF sweeps & PIM

100% factory testing of RF jumpers and feeder assemblies for return loss (VSWR) and passive intermodulation, for 4G/5G.

Environmental & mechanical

Tensile, crush, bend, impact and thermal cycling tests to Telcordia GR-20 and IEC methods.

Copper certification

Channel and permanent link certification on structured cabling to TIA and ISO limits.

Certifications

ISO 9001:2015

Quality management system (CQS Certification Services).

ISO 14001:2015

Environmental management system.

ISO 45001:2018

Occupational health and safety management.

DoT / TEC

Product conformity certificates from the Telecommunication Engineering Centre.

MSME ZED Gold

Zero Defect Zero Effect certification.

Registered trademarks

Semita and Semita Nexis brands.

Compliance

Standards by product family

Product familyStandardsKey metrics
Optical fiber & FTTx cableITU-T G.652.D, G.657.A1/A2, IEC 60794, Telcordia GR-20Attenuation at 1310/1550 nm, tensile, crush, water penetration
Fiber connectivity & MPOTelcordia GR-326-CORE, IEC 61754, TIA-604 (FOCIS)IL ≤ 0.20 dB (Elite ≤ 0.15), RL ≥ 60 dB APC
Optical transceiversSFF-8472, SFF-8436, SFF-8636, IEEE 802.3ba/bs/cdDOM telemetry, BER < 1E-12, wavelength stability
RF jumpers & feedersIEC 62037, IEC 60966, AISG 2.0 / 3GPPPIM ≤ -160 dBc, VSWR ≤ 1.15
Copper connectivityANSI/TIA-568.2-D, ISO/IEC 11801 Class E, RoHSChannel/permanent link to 250/500 MHz
NexisRack enclosuresEIA-310-E, IEC 60297, IP50 (IP55 optional)Integrated power, cooling, Modbus telemetry, static load
NexisODC cabinetsIEC 60529 (IP65), ETSI EN 300 019-1-1, IEC 60297-3-100Ingress, climatic classes, -48 V DC distribution

Need test reports for a tender?

We supply factory test data and compliance certificates with every order.