Tested before it leaves the factory
Every optical, RF and copper assembly we ship has been measured. Test reports and compliance certificates travel with the order.
Quality labs
Interferometry & polish
100% of optical patch cords and MPO connectors undergo 3D interferometer geometry inspection and automated end-face defect scanning.
RF sweeps & PIM
100% factory testing of RF jumpers and feeder assemblies for return loss (VSWR) and passive intermodulation, for 4G/5G.
Environmental & mechanical
Tensile, crush, bend, impact and thermal cycling tests to Telcordia GR-20 and IEC methods.
Copper certification
Channel and permanent link certification on structured cabling to TIA and ISO limits.
Certifications
ISO 9001:2015
Quality management system (CQS Certification Services).
ISO 14001:2015
Environmental management system.
ISO 45001:2018
Occupational health and safety management.
DoT / TEC
Product conformity certificates from the Telecommunication Engineering Centre.
MSME ZED Gold
Zero Defect Zero Effect certification.
Registered trademarks
Semita and Semita Nexis brands.
Standards by product family
| Product family | Standards | Key metrics |
|---|---|---|
| Optical fiber & FTTx cable | ITU-T G.652.D, G.657.A1/A2, IEC 60794, Telcordia GR-20 | Attenuation at 1310/1550 nm, tensile, crush, water penetration |
| Fiber connectivity & MPO | Telcordia GR-326-CORE, IEC 61754, TIA-604 (FOCIS) | IL ≤ 0.20 dB (Elite ≤ 0.15), RL ≥ 60 dB APC |
| Optical transceivers | SFF-8472, SFF-8436, SFF-8636, IEEE 802.3ba/bs/cd | DOM telemetry, BER < 1E-12, wavelength stability |
| RF jumpers & feeders | IEC 62037, IEC 60966, AISG 2.0 / 3GPP | PIM ≤ -160 dBc, VSWR ≤ 1.15 |
| Copper connectivity | ANSI/TIA-568.2-D, ISO/IEC 11801 Class E, RoHS | Channel/permanent link to 250/500 MHz |
| NexisRack enclosures | EIA-310-E, IEC 60297, IP50 (IP55 optional) | Integrated power, cooling, Modbus telemetry, static load |
| NexisODC cabinets | IEC 60529 (IP65), ETSI EN 300 019-1-1, IEC 60297-3-100 | Ingress, climatic classes, -48 V DC distribution |
Need test reports for a tender?