The cabling layer, engineered with the rack.
MPO/MTP fiber, optics to 400G, structured copper and out-of-band management, designed and certified by the team that builds NexisRack and NexisImmersion.

- Fibers per MPO
- 8–24
- QSFP-DD · QSFP112
- 400G
- Elite MPO insertion loss
- ≤ 0.12 dB
- Isolated management
- OOB
Portfolio

MPO/MTP high-density fiber
Base-8/12/16/24 trunks, cassettes, harnesses and 1U–4U enclosures, pre-terminated to your layout.
MPO/MTP
Data center optics, DAC & AOC
10G to 400G optics, breakouts, DAC and AOC, coded for your switches.
Optics
Structured copper
Cat6A and Cat8, pre-terminated trunks and 48-port 1U panels.
Copper
Out-of-band management
Console servers, management switching and cellular failover for unmanned sites.
OOBDesign, install, certify
Port design
Port maps, fiber counts, polarity plans and tray routing for ToR, EoR or MoR.
Pre-termination
Trunks and harnesses built to measured lengths, tested and labelled.
Install
Panels, cassettes and cable management inside the racks.
Certify
Fiber and copper certified to TIA/ISO limits with per-link results.
Document
TIA-606 labelling and as-built records.
Nexis Connect: Deployment Scope & FAQs
How Semita Nexis engineers, tests and supports Nexis Connect across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Nexis is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Nexis deliver and commission Nexis Connect in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Nexis customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.
Upgrading to 100G or 400G?
Send switch models and rack layout for a cabling and optics plan.