Brochures & Technical Guides Semita Technologies & Semita Nexis Corporate Overview & Product Specifications 2026 Datasheets
Semita Technologies — Semita & Nexis Contact us
Nexis Connect

Data center optics, DAC & AOC

MSA-compliant optics with DDM diagnostics, from 10G SFP+ to 400G QSFP-DD and QSFP112, validated for your switch and NIC vendors.

Semita MSA-Compliant Optical Transceivers from 1G SFP to 400G QSFP-DD

Product lines

SpeedForm factorVariants
10GSFP+SR, LR, ER
25GSFP28SR, LR
40GQSFP+SR4, LR4
100GQSFP28SR4, CWDM4, LR4
200GQSFP56SR4, FR4
400GQSFP-DD, QSFP112SR8, DR4, FR4, LR4

400G and 100G reference

OpticFiberConnectorReachUse
400G SR8OM4MPO-16100 mLeaf to spine within a hall
400G DR4OS2MPO-12 APC500 mSpine links; 4 × 100G breakout
400G FR4OS2Duplex LC2 kmBetween halls and buildings
400G LR4OS2Duplex LC10 kmMetro and edge interconnect
100G SR4OM4MPO-12100 mServer and leaf uplinks
100G LR4OS2Duplex LC10 kmEdge sites to core

Also: DAC for in-rack, AOC for adjacent racks, 400G-to-4 × 100G and 100G-to-4 × 25G breakouts. Diagnostics: temperature, voltage, bias and optical power.

Engineering & Procurement Guide

Data Center Optics, DAC & AOC: Deployment Scope & FAQs

How Semita Nexis engineers, tests and supports Data Center Optics, DAC & AOC across Indian enterprise, telecom and edge data center sites.

Factory Integration & 100% Pre-Dispatch Testing

Every system and connectivity assembly supplied by Semita Nexis is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.

Pan-India Site Check, Installation & SLA Support

Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.

How quickly can Semita Nexis deliver and commission Data Center Optics, DAC & AOC in India?

Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.

Can Semita Nexis customize configurations and provide project BOQs?

Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.

What certifications and test reports accompany each shipment?

All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.

Not sure which optic?

Tell us the switch, distance and fiber. We will specify the module and cabling.