Server room in a rack.
The NexisRack Smart Micro Data Center integrates IT racks, precision cooling, online UPS, monitoring, access control and optional fire suppression in one sealed enclosure. Models run from one rack to a five-rack edge facility. Larger multi-row builds are configured to order.

- PUE
- ≤ 1.4
- Power architecture
- 2N
- Noise at full load
- ≤ 49 dB
- Less floor area than a room
- ~40%
Six systems. One enclosure.
Precision cooling
Rack-mount or in-row AC with inverter compressor and double EC fans. 3.5–25 kW, ±0.5 °C, SHR 1, N+X group control, closed hot and cold aisles.
Power & UPS
Rack-mount online double-conversion UPS, 3–30 kVA, 2N architecture, Class C lightning protection, optional ATS, 15–120 minutes backup.
Smart monitoring
10.1″ 0U touchscreen tracking UPS, distribution, cooling, temperature, humidity, smoke, leakage and doors. Web, app and SMS alarms.
Nexis MonitorRack
IP50 (IP55 optional) fully enclosed 19″ rack, 28U usable in a single rack (up to 198U across NXM-5), ≤ 49 dB at full load, automatic emergency ventilation up to 5 kW.
Access & security
Door sensors as standard and an electronic keypad on every door, logged and managed remotely.
Fire suppression
Optional 1U heptafluoropropane (FM-200) clean-agent module that detects and extinguishes fire inside the rack.
Everything a server room needs, in 0.72 m²
- Power distribution module with live power display
- 3 kVA online UPS module, PF 0.8
- Battery packs: 8 batteries, 2U, 15 minutes
- 3.5 kW rack air conditioner, inverter + EC fans
- Optional 1U fire suppression module
- 10.1″ 0U monitoring screen
- LCD KVM console for local server access
- 28U IT space with 8-way 10 A PDU

NXM specifications
| Parameter | NXM-1 | NXM-2 | NXM-3 | NXM-5 |
|---|---|---|---|---|
| Power | ||||
| UPS capacity | 3 kVA | 6 kVA | 10 kVA | 20 kVA |
| Power factor | 0.8 | 0.8 | 0.8 | 0.9 |
| Total input | 220 V / 40 A | 220 V / 63 A | 220 V / 125 A | 380 V / 125 A |
| Rack | ||||
| Racks | 1 | 2 | 3 | 5 |
| Usable IT space | 28U | 33U + 42U | 29U + 2 × 42U | 30U + 4 × 42U |
| PDU per rack | 8-way 10 A | 12-way 10 A | 12-way 10 A | 12 × 10 A + 4 × 16 A |
| Cooling | ||||
| Cooling type | Rack-mount | In-row | In-row | In-row |
| Cooling capacity | 3.5 kW | 7.5 kW | 12.5 kW | 2 × 12.5 kW |
| Battery | ||||
| Standard batteries | 8 | 16 | 16 | 20 |
| 15 min backup | 2U battery pack | 3U battery pack | — | 6U battery pack |
| 40 min backup | — | — | — | External 20 × 100 Ah |
| Physical | ||||
| W × D × H (mm) | 600 × 1200 × 2000 | 1500 × 1200 × 2000 | 2100 × 1200 × 2000 | 3600 × 1200 × 2000 |
Common to all models: Class C lightning protection (ATS optional) · fully enclosed hot and cold aisle · compressor + EC fans, SHR 1, ±0.5 °C · emergency fans up to 5 kW with automatic start/stop · 0–45 °C, 0–95% RH, <1000 m altitude · optional 1U heptafluoropropane fire suppression · longer runtime with larger batteries or up to 4 extra packs. Specifications subject to change without notice. Final values are confirmed in each quotation.
Nexis Monitor, built in



NexisRack FAQs
Does NexisRack need a dedicated server room?
No. Sealed IP50 (IP55 optional) racks with closed hot and cold aisles run at 49 dB or less at full load, so they work in offices, branches, factory floors and telecom sites. The cooling unit needs an outdoor condenser position nearby.
How do I choose a model?
By IT load and rack space. NXM-1 is a single rack with 3 kVA and 28U. NXM-2, -3 and -5 add racks, UPS and in-row cooling. Larger builds are configured to order. Try the NexisRack sizer, then we confirm at site check.
What power supply does the site need?
220 V single-phase for NXM-1 to NXM-3, 380 V three-phase for NXM-5.
How long is the battery backup?
15 minutes as standard. Larger batteries or up to four extra packs extend it; NXM-5 can be built for 40 minutes or more.
What if the air conditioner fails?
Emergency fans of up to 5 kW start automatically and alarms go out at once. Larger systems can run N+X cooling redundancy.
How long from order to go-live?
Typically 6–10 weeks depending on configuration and battery runtime. Installation and commissioning on site take a few days.
What warranty and service do you offer?
12 months on the integrated system from commissioning, with annual maintenance contracts covering preventive visits, battery health checks and priority call-out.
Tell us the load. We will size the system.
Share IT load, rack count and backup time for a sized NexisRack proposal.