Copper Connectivity
Structured copper cabling for offices, plants and outdoor runs, certified to TIA and ISO limits.

Category 6 cable and components for horizontal cabling, industrial sites and outdoor runs. Channels are certified on a Fluke DSX tester when we install. For Cat6A and Cat8 in the data center, see Nexis Connect.
Products
6 product lines in this family.

CAT6 U/UTP 4-Pair Solid Cable
Unshielded solid copper horizontal cable for enterprise office runs, including high-power PoE.
SM-CAT6-UUTPSpecifications
CAT6 SF/UTP Double-Shielded Cable
Foil-and-braid shielded cable for high-interference sites such as factories and substations.
SM-CAT6-SFUTPSpecifications
Armoured CAT6 Direct-Burial Cable
Steel-tape armoured, water-blocking cable for burial without conduit.
SM-CAT6-ARMORSpecifications
Outdoor UV-Resistant CAT6 PE Cable
Polyethylene-jacketed cable for rooftop, wall and exterior runs.
SM-CAT6-OUTSpecifications
CAT6 & CAT6A Patch Leads
Factory-made RJ45 patch cords with gold-plated contacts and snagless boots.
SM-PATCH-C6Specifications
24-Port Keystone Patch Panel
1U 19-inch steel panel with toolless keystone jacks for organised copper termination.
SM-PP-24PORTSpecificationsAt a glance
| Product | Key spec 1 | Key spec 2 | Key spec 3 | Key spec 4 |
|---|---|---|---|---|
| CAT6 U/UTP 4-Pair Solid Cable | Category CAT6 | Bandwidth 250 MHz | Conductor 23 AWG | PoE 802.3bt |
| CAT6 SF/UTP Double-Shielded Cable | Category CAT6 | Shield SF/UTP | Use Industrial | Jacket LSZH / PVC |
| Armoured CAT6 Direct-Burial Cable | Category CAT6 | Armour Steel | Use Burial | Sheath PE |
| Outdoor UV-Resistant CAT6 PE Cable | Category CAT6 | Jacket UV PE | Use Outdoor | Box 305 m |
| CAT6 & CAT6A Patch Leads | Category CAT6 / 6A | Lengths 0.3–20 m | Contacts Gold | Colours 8 |
| 24-Port Keystone Patch Panel | Ports 24 | Height 1U | Jacks Keystone | Category CAT6 / 6A |
Copper Connectivity: Deployment Scope & FAQs
How Semita Technologies engineers, tests and supports Copper Connectivity across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Technologies is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Technologies deliver and commission Copper Connectivity in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Technologies customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.
Need a custom configuration?
Lengths, counts, connectors and labelling built to your drawing.