Armoured CAT6 Direct-Burial Cable
Steel-tape armoured, water-blocking cable for burial without conduit.
- Category
- CAT6
- Armour
- Steel
- Use
- Burial
- Sheath
- PE
Part code SM-CAT6-ARMOR · Made in India · Test report with every order
For links between buildings or to outdoor cameras where conduit is not practical. Gel or tape water-blocking keeps moisture out of the pairs.
Key features
- Corrugated steel tape armour
- Water-blocking
- Double PE sheath
Specifications
| Armour | Corrugated steel tape |
|---|---|
| Water blocking | Gel or swellable tape |
| Sheath | Inner + outer PE |
| Conductor | 23 AWG solid copper |
Typical values. Final specifications are confirmed in the product datasheet issued with each quotation. Custom builds available.
Standards
Applications
Campus inter-building
Outdoor CCTV
Industrial yards
Ordering
Quote the part code with the options you need. We confirm the full part number, lead time and test plan in our quotation.
- Base part code: SM-CAT6-ARMOR
- Specify length, count or configuration
- Specify connector, jacket or colour where relevant
- Add labelling or private-label requirements

Related products

CAT6 U/UTP 4-Pair Solid Cable
Unshielded solid copper horizontal cable for enterprise office runs, including high-power PoE.
View
CAT6 SF/UTP Double-Shielded Cable
Foil-and-braid shielded cable for high-interference sites such as factories and substations.
View
Outdoor UV-Resistant CAT6 PE Cable
Polyethylene-jacketed cable for rooftop, wall and exterior runs.
ViewArmoured CAT6 Direct-Burial Cable: Deployment Scope & FAQs
How Semita Technologies engineers, tests and supports Armoured CAT6 Direct-Burial Cable across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Technologies is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Technologies deliver and commission Armoured CAT6 Direct-Burial Cable in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Technologies customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.