Fiber Connectivity & Management
Passive fiber hardware from central office to customer premises: splitters, access terminals, frames, closures and factory-terminated cords.

Every patch cord and pigtail is polished, interferometer-checked and loss-tested in our labs. Splitters, terminals and closures are built for PON networks and the outdoor plant, with IP65 and IP68 enclosures designed for Indian monsoons.
Products
6 product lines in this family.

PLC Splitters (Cassette / ABS / Tube)
Planar lightwave circuit splitters for PON networks in bare fiber, steel tube, ABS box and LGX cassette formats.
SM-PLC-1XNSpecifications
Fiber Access Terminal (FAT 16F / NAP)
Pole or wall-mounted terminal that splits a feeder into 16 subscriber drops, IP65 sealed.
SM-FAT-16FSpecifications
Fiber Management System (Rack FMS / ODF)
19-inch sliding-drawer frames for patching and splicing in central offices, data centers and shelters.
SM-FMS-19Specifications
Joint Closure (JC 96F Flat / Inline)
Inline splice closure for manholes, handholes, aerial and direct-buried joints, IP68.
SM-JC-96FSpecifications
Fiber Patch Cords & Pigtails
Factory-terminated cords and pigtails, polished and interferometer-checked to Grade B or Elite loss.
SM-PC-OPTICSpecifications
Dome Splice Closure
Vertical dome closure for trunk and feeder joints, aerial or underground, 48–288 fibers.
SM-DSC-144FSpecificationsAt a glance
| Product | Key spec 1 | Key spec 2 | Key spec 3 | Key spec 4 |
|---|---|---|---|---|
| PLC Splitters (Cassette / ABS / Tube) | Ratios 1×2 to 1×64 | Window 1260–1650 nm | RL ≥ 55 dB | Temp. -40 to +85 °C |
| Fiber Access Terminal (FAT 16F / NAP) | Drops 16 | Splices 24 | Rating IP65 | Splitter 1×8 / 1×16 |
| Fiber Management System (Rack FMS / ODF) | Height 1U–4U | Density 48 LC / U | Splices 24–96 | Mount 19″ |
| Joint Closure (JC 96F Flat / Inline) | Splices 96 | Ports 4 | Rating IP68 | Impact IK10 |
| Fiber Patch Cords & Pigtails | IL (Elite) ≤ 0.15 dB | RL APC ≥ 65 dB | Polish UPC / APC | Durability 1000 matings |
| Dome Splice Closure | Capacity 48–288F | Ports 1 + 4 | Rating IP68 | Body PP |
Used in these solutions

FTTx & Broadband
Passive optical networks from the central office ODF through feeder and distribution to the customer drop, built to survive…
View solution
Data Center & Edge
From a branch server room to a GPU inference cluster: Semita Nexis delivers racks, cooling, cabling and monitoring as one…
View solutionQuestions
Can you supply splitters pre-loaded in FAT boxes?
Yes. FATs ship with the splitter installed and spliced, ready for feeder splicing in the field.
What is the difference between Elite and Grade B patch cords?
Elite cords have tighter polish geometry and lower insertion loss (≤ 0.15 dB), which matters on links with many connections or tight loss budgets such as 100G and 400G.
Fiber Connectivity & Management: Deployment Scope & FAQs
How Semita Technologies engineers, tests and supports Fiber Connectivity & Management across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Technologies is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Technologies deliver and commission Fiber Connectivity & Management in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Technologies customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.
Need a custom configuration?
Lengths, counts, connectors and labelling built to your drawing.