Brochures & Technical Guides Semita Technologies & Semita Nexis Corporate Overview & Product Specifications 2026 Datasheets
Semita Technologies — Semita & Nexis Contact us
Telecom & Fiber

Fiber Connectivity & Management

Passive fiber hardware from central office to customer premises: splitters, access terminals, frames, closures and factory-terminated cords.

Semita Passive Fiber Connectivity: Splitters, FATs, ODFs, Closures and Patch Cords

Every patch cord and pigtail is polished, interferometer-checked and loss-tested in our labs. Splitters, terminals and closures are built for PON networks and the outdoor plant, with IP65 and IP68 enclosures designed for Indian monsoons.

At a glance

ProductKey spec 1Key spec 2Key spec 3Key spec 4
PLC Splitters (Cassette / ABS / Tube)Ratios
1×2 to 1×64
Window
1260–1650 nm
RL
≥ 55 dB
Temp.
-40 to +85 °C
Fiber Access Terminal (FAT 16F / NAP)Drops
16
Splices
24
Rating
IP65
Splitter
1×8 / 1×16
Fiber Management System (Rack FMS / ODF)Height
1U–4U
Density
48 LC / U
Splices
24–96
Mount
19″
Joint Closure (JC 96F Flat / Inline)Splices
96
Ports
4
Rating
IP68
Impact
IK10
Fiber Patch Cords & PigtailsIL (Elite)
≤ 0.15 dB
RL APC
≥ 65 dB
Polish
UPC / APC
Durability
1000 matings
Dome Splice ClosureCapacity
48–288F
Ports
1 + 4
Rating
IP68
Body
PP

Questions

Can you supply splitters pre-loaded in FAT boxes?

Yes. FATs ship with the splitter installed and spliced, ready for feeder splicing in the field.

What is the difference between Elite and Grade B patch cords?

Elite cords have tighter polish geometry and lower insertion loss (≤ 0.15 dB), which matters on links with many connections or tight loss budgets such as 100G and 400G.

Engineering & Procurement Guide

Fiber Connectivity & Management: Deployment Scope & FAQs

How Semita Technologies engineers, tests and supports Fiber Connectivity & Management across Indian enterprise, telecom and edge data center sites.

Factory Integration & 100% Pre-Dispatch Testing

Every system and connectivity assembly supplied by Semita Technologies is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.

Pan-India Site Check, Installation & SLA Support

Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.

How quickly can Semita Technologies deliver and commission Fiber Connectivity & Management in India?

Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.

Can Semita Technologies customize configurations and provide project BOQs?

Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.

What certifications and test reports accompany each shipment?

All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.

Need a custom configuration?

Lengths, counts, connectors and labelling built to your drawing.