NexisRack NXM-3
A three-rack row with 12.5 kW in-row cooling and a 10 kVA UPS. Enough space for compute, storage and network for a campus, plant or hospital.
- Racks
- 3
- UPS
- 10 kVA
- Cooling
- 12.5 kW
- IT space
- 29U + 2 × 42U
Semita Nexis · Data center infrastructure by Semita Technologies
NXM-3 specifications
| Power supply & distribution | |
|---|---|
| UPS capacity | 10 kVA |
| Power factor | 0.8 |
| Total input | 220 V / 125 A · Single-phase |
| Protection | Class C lightning protection; ATS module optional |
| PDU per rack | 12-way 10 A |
| Rack | |
| Racks | 3 |
| Usable IT space | 29U + 2 × 42U |
| Aisle | Fully enclosed hot and cold aisle |
| Protection rating | IP50 standard; IP55 optional |
| Noise | ≤ 49 dB at full load |
| Emergency ventilation | Fan type, up to 5 kW, automatic start/stop |
| Cooling | |
| Type | In-row |
| Capacity | 12.5 kW |
| System | Inverter compressor + EC fans, SHR 1, ±0.5 °C |
| Battery | |
| Standard batteries | 16 |
| 15 min backup | — |
| 40 min backup | — |
| Longer runtime | Higher-capacity batteries or up to 4 extra packs |
| Physical & environment | |
| W × D × H (mm) | 2100 × 1200 × 2000 |
| Operating range | 0–45 °C, 0–95% RH non-condensing, <1000 m without derating |
| Fire | Optional 1U heptafluoropropane system |
| Monitoring | |
| Display | 10.1″ 0U touchscreen |
| Sensing | UPS, distribution, cooling, temperature, humidity, smoke, leakage, doors |
| Remote | Web, app, SMS alarms; multi-site platform |
Specifications subject to change without notice. Final values are confirmed in each quotation.
Where NXM-3 fits
- Manufacturing plants
- Hospitals and campuses
- Government edge rooms
- Edge AI Pod with NXL-20/40
Not sure? Use the NexisRack sizer or send us your load.

NexisRack NXM-3: Deployment Scope & FAQs
How Semita Nexis engineers, tests and supports NexisRack NXM-3 across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Nexis is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Nexis deliver and commission NexisRack NXM-3 in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Nexis customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.