NexisImmersion · NXL-10

NexisImmersion NXL-10

A 13U or 21U single-unit immersion tank rated for 10 kW of heat exchange. GPU inference nodes and dense 1U farms.

Heat exchange
10 kW
Tank
13U or 21U
Power
13U: 1~220 V · 21U: 3~380 V
Pipe
DN32

Semita Nexis · Data center infrastructure by Semita Technologies

Specifications

Heat exchange10 kW
Available U slots13U or 21U
Server height1U up to 13U or 21U, any mix
Average budget per U (full tank)0.77 (13U) · 0.48 (21U) kW
Pipe interfaceDN32
Cooling mediumSilicone oil recommended; mineral, synthetic and fluorinated fluids supported
Oil inlet / outlet40 °C / 50 °C
W × D × H (mm)13U: 1200 × 800 × 1250 · 21U: 1500 × 800 × 1250
Unit weight (empty)245 kg (13U) · 350 kg (21U)
Power supply13U: 1~220 V · 21U: 3~380 V
AccessTop access door with viewing window
PipingSide or bottom connections
MaterialsAll wetted parts stainless steel

Specifications subject to change without notice. Final values are confirmed in each quotation.

Example fill

3 × 4U GPU servers at 3 kW = 9 kW · 12U (13U tank), or 20 × 1U at 450 W = 9 kW · 20U (21U tank).

Planning illustration, not a validated configuration. Size for peak server power, not average.

Semita Nexis NexisImmersion Single-Unit Liquid Immersion Cooling Tank (NXL Series)
Engineering & Procurement Guide

NexisImmersion NXL-10: Deployment Scope & FAQs

How Semita Nexis engineers, tests and supports NexisImmersion NXL-10 across Indian enterprise, telecom and edge data center sites.

Factory Integration & 100% Pre-Dispatch Testing

Every system and connectivity assembly supplied by Semita Nexis is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.

Pan-India Site Check, Installation & SLA Support

Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.

How quickly can Semita Nexis deliver and commission NexisImmersion NXL-10 in India?

Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.

Can Semita Nexis customize configurations and provide project BOQs?

Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.

What certifications and test reports accompany each shipment?

All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.