NexisODC NXO-10 Outdoor Cabinet
10U ground-mount outdoor cabinet with 1600 W heat exchanger cooling for baseband and transport units.
- Rack space
- 10U
- HEX
- 1600 W
- Rating
- IP65
- Output
- 8 kW -48 V DC
Semita Nexis · Data center infrastructure by Semita Technologies
Specifications
| Capacity | |
|---|---|
| Rack space | 10U, 19″ (IEC 60297-3-100) |
| Equipment | Baseband and transport units; vendor agnostic |
| Environment | |
| Ingress protection | IP65 |
| Classes (ETSI EN 300 019-1-1) | 1.2 storage · 2.3 transport · 4.1 operation |
| Relative humidity | 15–100% |
| Climate · heat exchanger | |
| Temperature range | -33 °C to +55 °C |
| Cooling capacity | 1600 W |
| Mechanical | |
| Dimensions (H × W × D) | 1200 × 650 × 700 mm incl. 150 mm base frame |
| Weight | < 95 kg, excluding active equipment |
| Mounting | Ground |
| Material | Galvanized steel |
| Colour | Powder paint, RAL 7035 |
| Door / lock | Front access · padlock |
| Power system | |
| Input voltage | -48 V DC |
| Operating input range | -40.0 to -58.5 V DC |
| Max input current | 200 A |
| Output voltage range | -39.5 to -58.5 V DC |
| Output load | Max 8 kW: priority up to 2.5 kW, main up to 7 kW |
| Circuit breakers | 10 priority load · 13 main load |
| Cable I/O | |
| Entry point | Bottom; plinth access from rear and side |
| DC in (battery feed) | 4 × Ø19 mm |
| DC out (shielded) | 18 × Ø10–18 mm |
| Signal outlet / inlet | 10 × Ø10 mm / 8 × Ø6 mm |
| Optical | 22 × Ø6 mm |
| Punched holes | 3 × Ø26 mm |
| Remote management | |
| External alarms | Door · fan · HEX · DC SPD |
Specifications subject to change without notice. Final values are confirmed in each quotation.
NexisODC NXO-10: Deployment Scope & FAQs
How Semita Nexis engineers, tests and supports NexisODC NXO-10 across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Nexis is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Nexis deliver and commission NexisODC NXO-10 in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Nexis customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.