Edge Hub
Regional compute with in-row cooling and large-capacity UPS: NXM-3 or NXM-5.

Who it is for
- Regional enterprises
- Manufacturing campuses
- Government data centers
Why it works
- Data-center grade in weeks, not months
- Scales by adding cabinets
- PUE ≤ 1.4
Other packages

Nexis Edge AI Pod
Air-cooled IT and immersion-cooled GPUs in one footprint, cabled for 400G and monitored from one screen.
View
Branch Micro DC
A complete branch server room in 0.72 m²: NXM-1 with 3 kVA UPS, 28U IT space and monitoring.
View
Business Outlets
Standard edge sites for telecom, finance, energy, broadcast and retail networks, with central monitoring.
ViewNexis Edge Hub Micro Data Center: Deployment Scope & FAQs
How Semita Nexis engineers, tests and supports Nexis Edge Hub Micro Data Center across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Nexis is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Nexis deliver and commission Nexis Edge Hub Micro Data Center in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Nexis customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.