Case study · Telecom

Outdoor cabinets for street-level small cells

Pole-mounted NexisODC NXO-05 cabinets with -48 V DC distribution and alarms for dense urban small cells.

Semita Nexis NexisODC NXO-05 IP65 Outdoor Telecom Cabinet
Sector
Telecom / neutral host
Scope
Urban small cells
Products
NexisODC NXO-05, hybrid cable, SPD
Mount
Pole

The challenge

  • Urban small cells need baseband and transport at street level, with no shelter.
  • Equipment must survive heat, dust and monsoon rain.

The solution

  • NexisODC NXO-05 on the pole: 5U vendor-agnostic space, IP65, 800 W heat exchanger.
  • Integrated -48 V DC with priority and main load breakers.
  • Hybrid fiber/power drops to the radio, SPDs on DC and RF.
  • Door, fan/HEX and SPD alarms to the NOC.

What it delivers

  • A sealed, alarmed cabinet in a compact pole-mounted footprint.
  • One kit per site: cabinet, cable, protection.

This is a reference deployment scenario. It shows how Semita typically designs and delivers this type of project, with customer details withheld. Outcomes describe the design targets and expected results for this configuration, not measured results from a named customer. Ask us for references in your sector.

Engineering & Procurement Guide

Outdoor Cabinets for Small Cells: Deployment Scope & FAQs

How Semita Technologies engineers, tests and supports Outdoor Cabinets for Small Cells across Indian enterprise, telecom and edge data center sites.

Factory Integration & 100% Pre-Dispatch Testing

Every system and connectivity assembly supplied by Semita Technologies is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.

Pan-India Site Check, Installation & SLA Support

Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.

How quickly can Semita Technologies deliver and commission Outdoor Cabinets for Small Cells in India?

Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.

Can Semita Technologies customize configurations and provide project BOQs?

Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.

What certifications and test reports accompany each shipment?

All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.