Rack & Custom Power Assemblies
Custom-length equipment harnesses and PDU input whips from busway or floor panel to rack.
- Plugs
- C13–C20
- Industrial
- IEC 60309
- Build
- To drawing
- Use
- Racks
Part code SM-PWR-CABINET · Made in India · Test report with every order
Power cords and whips built to drawing for data centers and equipment rooms: IEC C13/C14, C19/C20, industrial plugs and hard-wired tails.
Key features
- IEC C13/C14, C19/C20
- IEC 60309 industrial plugs
- Custom lengths and colours
Specifications
| Connectors | IEC 60320 C13/C14/C19/C20, IEC 60309, IS 1293 |
|---|---|
| Conductor | 1.0–6 mm² |
| Lengths | Any |
| Jacket | PVC or LSZH, colour coded |
Typical values. Final specifications are confirmed in the product datasheet issued with each quotation. Custom builds available.
Standards
Applications
PDU inputs
Server power cords
Equipment harnesses
Ordering
Quote the part code with the options you need. We confirm the full part number, lead time and test plan in our quotation.
- Base part code: SM-PWR-CABINET
- Specify length, count or configuration
- Specify connector, jacket or colour where relevant
- Add labelling or private-label requirements

Related products

RRU / BBU Telecom Power Assemblies
Factory-terminated -48 V DC feeds from rectifiers to tower-top radios and baseband units.
View
Shielded / Screened DC Power Cable
DC power cable with a tinned copper braid that keeps switching noise away from RF feeders.
View
Armoured & Multi-Core Power Cable (SWA)
Steel-wire armoured multi-core cable for trench burial between supply, generator and shelter.
ViewRack & Custom Cabinet Power Assemblies: Deployment Scope & FAQs
How Semita Technologies engineers, tests and supports Rack & Custom Cabinet Power Assemblies across Indian enterprise, telecom and edge data center sites.
Factory Integration & 100% Pre-Dispatch Testing
Every system and connectivity assembly supplied by Semita Technologies is built under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 quality management across our five Indian manufacturing units in Bengaluru, Mysore, Bhiwadi and Surat. Optical assemblies undergo 100% insertion-loss and return-loss verification, RF assemblies are PIM and VSWR swept, and micro data center racks undergo full thermal and UPS load testing prior to dispatch.
Pan-India Site Check, Installation & SLA Support
Our own field engineering teams conduct pre-deployment site checks covering power, earthing, floor loading, thermal heat rejection and cable pathways. We deliver complete bills of quantities (BOQs), CAD layout drawings, on-site commissioning and annual maintenance contracts (AMC) with 24×7 remote telemetry monitoring and guaranteed response SLAs.
How quickly can Semita Technologies deliver and commission Rack & Custom Cabinet Power Assemblies in India?
Standard connectivity, optical transceivers, fiber cables and rack accessories ship from our Indian plants within 1 to 3 weeks. Pre-integrated NexisRack micro data centers typically ship in 6 to 10 weeks and NexisImmersion liquid cooling systems in 8 to 12 weeks, with on-site installation and commissioning completed in a few days.
Can Semita Technologies customize configurations and provide project BOQs?
Yes. Our application engineers size and customize fiber core counts, trunk breakout lengths, transceiver vendor coding, rack U-heights, UPS battery runtimes and cooling capacities to match your exact site and workload. Contact our engineering team at sales@semita.in or +91-92122-94293 for a tailored BOQ within one business day.
What certifications and test reports accompany each shipment?
All deliveries include factory serialized test reports (OTDR traces, IL/RL certificates, PIM sweep charts or integrated rack FAT protocols) along with ISO 9001/14001/45001, RoHS, CE and applicable DoT/TEC conformity documentation.